Alarm setting range | (1) Acceleration: 1 to 99m / s2 (Peak) (2) Velocity: 1 to 99mm / s (Peak) (3) Displacement: 0.01 to 0.99mm (PP) |
Frequency range | Acceleration: 5 to 500Hz Velocity / displacement 10 to 500Hz (+ 5%, -10%) |
Accuracy | Within 5% (25 ℃, 80Hz, 10m / s2, sine wave) |
Straightness | Within 1% of full scale |
Drive power supply | DC24V ± 0.5V, 12mA (typ), 20mA (max) |
2-system relay output | Operation delay 0 to about 60 seconds (internally variable) Self-holding operation 1 system (A contact) Automatic recovery operation 1 system (A contact) Contact rating AC / DC 125V, 0.5A |
Housing structure | Material Aluminum (with nitrile rubber packing) Protective structure IP-64 |
Vibration resistance | Vibration 100m / s2, Impact 1,000m / s2 |
Withstand voltage | Relay contact-housing AC 1,500V 1 minute Relay contact-power supply (24V) AC 1,500V 1 minute Power line connected to housing at 0.1μF |
Compatible wire | 0.2-2.5mm2 (AWG24-16) |
Compatible cable | Cable outer diameter: Standard φ11 to 13 mm (can be specified in the range of φ7 to 13 mm at the time of shipment) |
Temperature range | Use -10 ℃ ~ + 70 ℃ Storage -20 ℃ ~ + 80 ℃ |
Dimensions / mass | (W) 90 × (H) 56 × (D) 70mm Approx. 700g |