±0.038 m/s to 12.2 m/s (±0.125 ft/s to 40 ft/s) in most applications
Pipe Size
Any pipe ID from 12.7 mm to 4.5 m (0.5 in to 180 in)
Accuracy
±2% of reading or 0.03 m/s (0.1 ft/s). Requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability: ±0.1%, Linearity ±0.5%
Display
White, back-lit matrix - displays flow rate, totalizer, relay states, 16-digit totalizer, operating mode, and calibration menu
Calibration
Built-in 5-key calibrator with English, French, or Spanish language selection
Power Input
100-240 V AC 50/60 Hz, (see Options) 2.4-5.6 W depending on options
Single-head ultrasonic. Designed to withstand accidental submersion to 10 psi. Certified non-incendive for Class 1 Div 2, Groups A, B, C, D hazardous locations
Operating Temperature
-15 °C to 80 °C (5 °F to 175 °F)
Sensor Cable
6 m (20 ft) shielded cable
Sensor Mounting
Stainless steel mounting kit for pipes 12.7 mm (0.5 in) ID or larger
Options
Options:
Description:
Sensors
Intrinsic Safety Barriers for Sensor mounting in Class 1 Div 1 hazardous locations
Sensor Cable
15 m (50 ft) or 30 m (100 ft), continuous shielded coaxial pair, or splice up to a total of 152 m (500 ft) with Junction Box. Self tunes to extended cable.
Enclosure Heater
For outdoor installation, 16 W thermostatically controlled to -40 °C (-40 °F)
Data Logger
Built-in 2 million point logger with a USB output and Windows software
Power Input
9-32 V DC, 2.1 W to 4.95 W depending on options
Control Relays
4 additional (6 total) rated 5 A SPDT