Home | Contact | Sitemap | Admin
  • > 데이터로거
  • > 고속 데이터로거
  • > GRAPHTEC CORPORATION
  • > midi LOGGER
4-ch High Speed & Voltage Data Logger
Art.-No. GL-2000 Series
모델명 Art.-No. GL-2000 Series
제조사 GRAPHTEC Corporation
원산지 일본
분류명 다채널 데이터 로깅시스템

Specifications


ItemDescription
Display (LCD)Size7-inch TFT color LCD (WVGA: 800 x 480 dots)
InformationWaveform in Y-T with digital values, Enlarged waveforms, Digital values and Real-time statistical result values, XY graph
LanguageEnglish, French, German, Spanish, Russian, Chinese, Korean, Japanese
Interface to PCTypeEthernet (10 BASE-T/100 BASE-TX), USB2.0
FunctionData transfer to PC (up to 1 ms sampling), Control command to GL2000
Ethernet functionsWeb server function, FTP server function, NTP client function, DHCP client function, Email send function
USB functionUSB mode (File transfer and deletion from built-in flash and SD on GL2000)
Trigger functionTrigger actionStart or stop capturing data by triggering
Trigger source• Start: Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time
• Stop: Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time
CombinationLevel OR, Level AND, Edge OR, Edge AND
Threshold• Analog (*1): High or Low in level mode, Rising or Falling in edge mode,
  Window-in, Window-out
• Logic: H or L (4-channel signal pattern)
• Pulse: High or Rising, Low or Falling, Window-in, Window-out
Repeat actionOff, On (Re-armed automatically)
Trigger hold outHold off repeat action in specified period
• Mode: Previous start to next start, previous stop to next start
• Time: zero second (no hold off) to 9999 hrs. 59 min. 59 sec
Defection accuracy± 0.5 % of measurement range
Pre-triggerUp to the number of capturing data points (max. 4000000)
specified in built-in RAM (only when built-in RAM is used)
Alarm functionAlarm actionDisplays and outputs a signal when alarm is detected
Threshold• Analog input: High, Low, Window-in, Window-out
• Logic input: H or L (signal in each channel)
• Pulse input: High or Rising, Low or Falling, Window-in, Window-out
CombinationOR (Source channel can be assigned with OR condition to output port)
Detection cycleLink with analog sampling
Alarm holdingOn or Off
Detection accuracy± 0.5 % of measurement range
Storagve deiceBuilt-in RAMFour million samples for each channel
• Memory partition: 4 M samples x 1 bank, 2 M sample x 2 banks,
  1 M samples x 4 banks, 500 k samples x 8 banks
• Capturing data points: Specified 10 to 4000000
• Data type: Captured data
• Auto-save: Transfer captured data to other devices after capturing is completed
  (It can be enabled or disabled)
Built-in Flash4 GB (for capacity of data: approx. 3.9 GB)
• Data type: Captured data, Condition settings, Screen copy
External USB (*2)Support USB Flash memory device (*3) by USB2.0 Type A port, Single port, No memory capacity limit
• Data type: Captured data, Condition settings, Screen copy
External
SD CARD (*2)
Support SDHC memory card (up to 32 GB) by SD Card slot, Single slot
• Data type: Captured data, Condition settings, Screen copy
Capturing modeModeOff (Normal), Ring, Relay
Off (Normal)Save data between start to stop
Ring (*4)Save most recent data of specified number
• Destination: Built-in RAM, Built-in Flash, USB or SD
• Number of capturing data: 1000 to 10000000 data (*5)
• Sampling: up to 1 MS/s (interval 1 μs) in built-in RAM,
  up to 1 kS/s (interval 1 ms) with GBD format in other device,
  up to 100 S/s (interval 10 ms) with CSV format in other device
RelaySave data to multiple files with specified capturing time or file size (up to 4 GB) until recording data is stopped
• Destination: Built-in Flash, USB or SD
• Sampling: up to 1 kS/s (interval 1 ms) with GBD format,
  up to 100 S/s (interval 10 ms) with CSV format
Data backupIntervalOff, 1, 2, 6, 12, 24 hrs., specific time, or any time with key operation
• Sampling: up to 1 kS/s (interval 1 ms) with GBD format,
  up to 100 S/s (interval 10 ms) with CSV format
File destinationBuilt-in Flash, USB or SD
Hot-swapping
external memory
Hot-swapping USB or SD Flash memory with key operation during data backup
Search functionFunctionSearch for specific point in captured data
Search factor• Analog: Signal levels in each channel
• Logic: 4-channel signal pattern
• Pulse: Rising, Falling, Window-in, Window-out in each channel
• Alarm: Alarm occurring point
Calculation functionStatisticalReal-time: Display digital and statistical values at the same time
• Function: Maximum, Minimum, Peak-to-peak (P-P), Average
Replay: Statistical values between cursors in replay captured data
• Function: Maximum, Minimum, Peak-to-peak (P-P), Average, RMS
Between channelsAddition, subtraction, multiplication and division for two analog inputs (only in GBD format)
Scaling (Engineering unit) functionMeasured value can be converted to the specified engineering unit
• Analog voltage: Converts using four reference points (gain, offset)
• Temperature: Converts using two reference points (offset)
• Pulse count: Converts using two reference points (gain)
Annotation functionComment can be set in each channel, up to 31 alphanumeric
characters and symbols (Display first 8 characters on screen)
Operating environment0 to 40 ºC when driven by AC adapter or battery, 5 to 85 % RH (non condensed)
Power sourceAC adapter: 100 to 240 V AC, 50/60 Hz
DC power: 8.5 to 24 V DC (required cable option B-514)
Battery pack: Two battery packs (option B-569) required
Power consumptionAC adapter
(in 240 V AC)
Approx. 39 VA (59 VA while charging battery) with disabling screen saver
Approx. 34 VA (55 VA while charging battery) with enabling screen saver
DC drive (24 V)Approx. 0.5 A (0.81 A while charging battery) with disable screen saver
Approx. 0.43 A (0.76 A while charging battery) with enabling screen saver
DC drive (12 V)Approx. 1 A (Cannot charge battery) with disable screen saver
Approx. 0.85 A (Cannot charge battery) with enabling screen saver
DC drive (8.5 V)Approx. 1.46 A (Cannot charge battery) with disable screen saver
Approx. 1.22 A (Cannot charge battery) with enabling screen saver
External dimensions [W×H×D]Approx. 260 x 161 x 83 mm (with the cover)
WeightApprox. 1.7 kg (the cover is attached, AC adapter and battery are not included)
Vibration resistanceCompatible with JIS Vibration test method for automobile Type 1 Class A (Vibration durability test: 5 m/s²)


Standard Accessories


  • AC adapter with power cable
  • Quick start guide and Safety guide
  • CD-ROM (PC application software, User manual)
  • Cover (attached to the main body)
  • Tilt stand set (including mounting screws M4)
  • Screws (M3.5) for input terminal
  • Ferrite core (attach to cable for radiation reduction)

  • 파일명 확장자 다운로드
     Art.-No. GL-2000 Series[Brochure].pdf (788KB)


    상호 : 주식회사 마스  |  (우)13209 경기도 성남시 중원구 사기막골로 45번길 14 우림2차 A-1610호   |   Tel : 031-735-6310 / 6320   |   Fax : 031-735-6334
    대표이사 / 개인정보관리책임자 : 안승만   |   사업자등록번호 : 129-86-80575   |   통신판매업등록번호 : 제2013-경기성남-0854호   |   메일 : mmm@m-m.co.kr

    COPYRIGHT© MAS CO.,LTD. ALL RIGHTS RESERVED.