FLOW MEDIUM Please note that PWE Flow Meters
are designed to work only with liquids. Never try to measure flow rates of dry
gas. |
CALIBRATIONS Performed at standard conditions
[14.7 psia (101.4 kPa) and 70°F (21.1°C)] unless otherwise requested or
stated. |
VISCOSITY Calibrated to 1 cSt (water). Meters
with display can be used for fluids up to 50 cSt with field calibration (maximum
flow range may be affected). |
ENVIRONMENTAL (PER IEC 664) Installation Level
II; Pollution Degree II. |
FLOW ACCURACY (INCLUDING LINEARITY) ±1% of
FS |
REPEATABILITY ±0.25% of full
scale. |
FLUID TEMPERATURE MEASURMENT RANGE* -10 to 70
°C |
TEMPERATURE ACCURACY (INCLUDING LINEARITY)*
±0.5 °C |
FLOW RESPONSE TIME approximately 1 seconds
(above 10% of full scale flow), approximately 2 seconds (below 10% of full scale
flow) |
MAXIMUM PRESSURE 10 bar (150
psi) |
MAXIMUM PRESSURE DROP 1.4 bar (20 psi) at
132.5 L/min flow. See Table IV for pressure drops associated with various models
and flow rates. |
FLUID AND AMBIENT TEMPERATURE 14°F to 160°F
(-10°C to 70°C) |
OUTPUT SIGNALS
|
Power consumption: |
|
Linear 0-5 Vdc (3000 ohms min load impedance) |
|
Linear 4-20 mA (500 ohms maximum loop resistance) |
|
Maximum noise 20mV peak to peak (for 0-5 Vdc output) |
|
Flow Pulse Output: 3.3 Vdc amplitude (3000 ohms min load
impedance) | |
OPTICALLY ISOLATED OUTPUTS UCE @ 40Vdc, ICE @
150 mA |
FLOMETER INPUT POWER 11 to 26 Vdc, 100 mV
maximum peak to peak output noise
|
Power consumption: |
|
+12Vdc (150 mA maximum) |
|
+24Vdc (100 mA maximum) | Circuit board have built-in
polarity reversal protection, 300mA resettable fuse provide power input
protection. |
COMMUNICATIONS PARAMETERS (RS-232/RS-485)
|
Baud rate: .................... 9600 baud |
|
Stop bit: ....................... 1 |
|
Data bits: ...................... 8 |
|
Parity: .......................... None |
|
Flow Control: ...............
None | |
DISPLAY* Optional local 2x16 characters LCD
with adjustable backlight (2 lines of text). |
KEY PAD* Optional 4 push button key
pad. |
CE COMPLIANCE EMC Compliance with 89/336/EEC
as amended. Emission Standard: EN 55011:1991, Group 1, Class A Immunity
Standard: EN 55082-1:1992 |